Mobile Incineration Solutions for Coal Mines and Open-Pit Mining Operations

Mobile Incineration Solutions for Coal Mines and Open-Pit Mining Operations


Mining activities―whether in underground coal mines, open-pit extraction areas, or explosive storage zones―generate a diverse range of waste types that require safe, efficient, and mobile treatment solutions. Waste from canteens, explosive packaging, oil-stained tarpaulins, and used protective clothing cannot be safely buried or burned openly. The mobile dual-chamber incinerator from HICLOVER provides a practical and compliant solution designed specifically for remote mining environments.


Challenges in Waste Disposal at Mining Sites

In coalfields across regions such as Inner Mongolia, South Africa, and Western Australia, mine operations are spread across wide and often shifting areas. Camps and work zones frequently move as new shafts or pits are developed. This mobility complicates waste collection and disposal. Transporting waste long distances is costly, and local dumping can contaminate groundwater and attract vermin.

For explosives warehouses and fuel depots, environmental safety requirements are even stricter. Open burning risks ignition, while storing combustible waste near operational zones violates most mine safety and environmental codes.


HICLOVER Mobile Dual-Chamber Incinerator

The mobile dual-chamber incinerator is built on a thermal-insulated trailer chassis, allowing it to be easily towed between mining sites. It includes two combustion chambers:

  • Primary Chamber C Designed for mixed solid waste such as oily cloth, packaging, and organic material.

  • Secondary Chamber C Operates above 1100°C, ensuring full burnout of gases and particulates for clean emissions.

Each system is diesel-fueled or optionally LPG-compatible, featuring PLC temperature control, automatic ignition, and stainless-steel stack for durability.

Learn more about key system components:


Why Mobility Matters for Mining Operations

Mines expand and relocate as extraction progresses. Permanent waste treatment plants are not cost-effective in these transient settings. HICLOVER’s trailer-mounted incinerator can be deployed directly beside underground dormitories, canteens, or maintenance areas, eliminating waste transport needs and improving hygiene on-site.

Key benefits include:

  • Rapid deployment without civil works.

  • Heat-insulated trailer base suitable for high-altitude or cold-climate mines.

  • Compact footprint, ideal for confined camp layouts.

  • Low fuel consumption, supporting continuous operation with minimal maintenance.

  • Emission compliance with GB18484-2020 and WHO field standards.


Environmental and Operational Advantages

Mining companies in areas such as Zambia’s Copperbelt, Indonesia’s coal basins, and Kazakhstan’s open-pit fields increasingly face scrutiny from local environmental authorities. Adopting self-contained mobile incineration units helps ensure compliance, improves worker safety, and demonstrates environmental responsibility.

Paired with optional wet scrubbers or activated carbon filtration systems, HICLOVER solutions minimize visible smoke and odor, meeting modern environmental expectations even in remote industrial zones.

Explore more sustainable waste handling systems:


HICLOVER ― Portable, Durable, and Compliant Waste Incineration for Global Mining and Resource Operations.

Mobile: +86-13813931455(WhatsApp)

Email:     [email protected]     
Email:     [email protected] 

 

2025-11-03/14:22:34

Incinerator Items/Model

HICLOVER TS100(PLC)

 

Burn Rate (Average)

100kg/hour

Feed Capacity(Average)

150kg/feeding

Control Mode

PLC Automatic

Intelligent Sensor

Continuously Feeding with Worker Protection

High Temperature Retention(HTR)

Yes (Adjustable)

Intelligent Save Fuel Function

Yes

Primary Combustion Chamber

1200Liters(1.2m3)

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Burner Type

Italy Brand

Temperature Monitor

Yes

Temperature Thermometer

Corundum Probe Tube, 1400℃Rate.

Temperature Protection

Yes

Automatic Cooling

Yes

Automatic False Alarm

Yes

Automatic Protection Operator(APO)

Yes

Time Setting

Yes

Progress Display Bar

3.7 in” LCD Screen

Oil Tank

200L

Chimney Type

 Stainless Steel 304

1st. Chamber Temperature

800℃–1000℃

2nd. Chamber Temperature

1000℃-1300℃

Residency Time

2.0 Sec.

Gross Weight

7000kg

External Dimensions

270x170x190cm(Incinerator Main Body)

Burner operation

Automatic On/Off

Dry Scrubber

Optional

Wet Scrubber

Optional

Top Loading Door

Optional

Asbestos Mercury Material

None

Heat Heart Technology(HHT)

Optional

Dual Fuel Type(Oil&Gas)

Optional

Dual Control Mode(Manual/Automatic)

Optional

Temperature Record

Optional

Enhanced Temperature Thermometer

Optional

Incinerator Operator PPE Kits

Optional

Backup Spare Parts Kits

Optional

Mobile Type

Optional:Containerized/Trailer/Sledge Optional