Common 10kgs per human resources burner for small Healthcare facility – Waste Incinerators

This equipment quality structural for kinds of site, like hospital, environmental department,  animal cremation agencies, etc.  HICLOVER Incinerator supply updated models with dual combustion chamber,  mix-combustion chamber and smoke filter  chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C. Tools Technical Specifications Version YD-10C Image Feed Capability Common 40 kgs…

Read More

incinerator manufacturer – Waste Incinerators

“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must prevent the discharge of black smoke and fine dust, during the loadings. It shall have the ability to reduce the quantity of wastes by 98%. It shall have the ability to hold emission in the second burn with gas residence of not less…

Read More

animal incinerator for sale – Waste Incinerators

The incinerator shall be supplied with a range of interconnecting ductwork between the thermal reactor outlet and the inlet of the chimney. This ductwork will consist of refractory lined tubes and higher temperature resistant tubes made from rolled sheet steel of minimum 3mm thickness, welded along the length.   The standard chimney shall be made…

Read More

small incinerators – Waste Incinerators

The incinerator shall be equipped with water injection nozzle link. If the temperature in the primary chamber should rise too high (normal temperature between 300 and 800? C) during the working time, the automated water injection shall be actuated to decease the temperature.   The incinerator shall have the following features and facilities:-   a-   …

Read More

00 BEDS HOSPITAL INCENERATOR TECHNICAL INFORMATIONS – Waste Incinerators

1) Policy – Waste disposal management shall be taken special note to reduce hospital infection. – Infections wastes shall be managed, stored strictly and burnt by a incinerator located at hospital website.   2) Waste Disposal Plan a)Classification – Medical wastes in hospital are classified as follows;   Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste…

Read More

30kgs medical waste heater Design TS30 PLC. – Waste Incinerators

30kgs per hour(average) medical waste incinerator, design dual  combustion chambers(primary chamber and secondary chamber),  smoke filter chamber, PLC auto. control system, 0.33m3(330liters) primary combustion chamber, italy oil or gas fuel burner. for small  hospital medical waste treatment. Buy waste incinerator, find hiclover Items/Model TS30 PLC Idea Waste Incineration Burn Rate Criterion 30kgs/hour Gas Kind Diesel Oil/Natural…

Read More

50kgs per hour burner with Two chambers vendors from china – Waste Incinerators

50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters primary combustion chamber *Italy burner *Stainless steel chimney Variation YD-50 Burning Cost Average 50 kgs/hour Feed Ability Typical 150 kgs Primary Burning Chamber 900 Litres Additional Combustion Chamber 300 Litres Mix Burning Chamber Yes Smoke…

Read More

medical waste – Waste Incinerators

———————————–   Failure to establish the authenticity of the certificate the bidder is liable to render the bid non-responsive and bidder open to action in the line with applicable regulations and act. Original catalogue must be submitted Original data sheet must be submitted   Solidifier (Fluid waste disposal Product) Particular Features of Solidifier 21b jar…

Read More

China mobilises medical groups to fight new coronavirus – Waste Incinerators

By Thursday midnight, Hubei Province in central China reported 549 cumulative confirmed cases of the new coronavirus pneumonia, with 495 in Wuhan, the provincial capital. Nationwide, 29 provincial-level regions have reported confirmed cases. Twenty four deaths from the infection were reported in Hubei and one was in the northern Hebei Province, the National Health Commission…

Read More

Heater YD-30 for Australia – Waste Incinerators

2nd Chamber (Liters). Items/Model1000 ℃ -1200 ℃. UNDOUBTEDLY. Mix-Combustion Chamber.30 kgs/Hr.200. Outdoors Dimensions (cm).100x60x60.INDEED. Smoke Filter Chamber.145x90x175. Inside Measurements (centimeters).Stainless-steel. Additional Chamber.60 kgs. Tools Weight. Heater Design YD-30 for Australia Melbourne client.5. Chimney Kind. CERTAINLY. Combustion Fuel.2.0 Sec. Temperature level Tracking. YES. First. Chmaber Temperature degree.200. Door Opening (centimeters).48 x 60. Smokeshaft (M).Oil/Gas. Residency Time.800…

Read More

Heater YD-100 for Iraq – Waste Incinerators

There are 03 sets Design YD-100 circulation to Iraq between year 2013 to 2014. The heater use for neighborhood a range of structure in addition to construction sites along with all gas type is diesel oil. Items/Model YD-100 Burning Rate (kgs/Hour) 100 kgs/Hr. Feed Capacity (kgs) 200 kgs Equipment Weight 5300 kgs Primary Chamber (Liters)…

Read More

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals in Kenya – Waste Incinerators

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals   All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation (26, 47) pertaining classification, standards, criteria, and procedure for installing/operating incinerators as authored by the National Environmental Management and Coordination (waste management) regulation 2006, legal notice…

Read More