https://gudaobian.net/incineration/pet-crematory-2/
https://gudaobian.net/incineration/pet-crematory-2/
https://gudaobian.net/incineration/pet-crematory-2/
Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system Per your advertisement for 300 kg.hr. Model – We will need to know the purchase price via return. How many Kg. Of Fuel would be required for running this Model 10 hrs. everyday. We’ve got our very own Freight Forwarding Agent. We had a…
Equipment Access Openings: Organize all piping and equipment to allow access to openings without disassembly of piping or equipment. Provide space which permits full opening of all doors, panels, and other access openings. Operating Space: Do not reduce or alter personnel working spaces shown except with prior approval of Resident Engineer. Fuel Oil…
A chamber of post combustion of gases * A burner of combustion of gases, * A device of injection of air allowing a total recombustion of gases, * A device of air inlet of cooling of waste gases, * A sheath of evacuation of the gases burnt. * Carcass in strong sheet steel with assistance…
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L…
The incinerator will then take supply from the DO tank through its DO feed pumps to its respective burners. An incorporating meter shall be installed to measure the quantity of DO consumed by the incinerator. The meter will have a digital read out in litres and will record quantities from 1 to 99999 with an…
Test shall be conducted by factory authorized representative of incinerator manufacturer. Demonstrate required weight reduction of specified waste. Waste shall be fed in a single batch to the unit. After termination of manufacturer’so-called burning period, inspect and weigh the residue. Emissions testing may be deleted if not required by state or local authorities….
Including:Incinerator: Structure to be specified – A receiving cage for biomedical waste; – A combustion chamber using a chimney using a filter to keep the ashes; Chimney section: about 300 cm; using a minimum height of 6 m Door dimensions: approximately 50×60 cm Supplied with a 500 liters fuel tank and all necessary accessories for…
https://gudaobian.net/incineration/hazardous-waste-incinerators-in-china/
Fully automatic sequential control provided by internal Secondary chamber pre-heat Burn cycle (variable) Cool down cycle PLC system providing control of: Gas Alternatives Diesel, LPG, Natural or Bio Gas. Average Gas Consumption Diesel: 8 / 10 litres per hour Liquid Propane Gas: 6 / 8 litres per hour Natural Gas: 7 / 9 Nm3 per…
Programming controls. planned method. Appropriate prepurge, ignition, postpurge, and modulation ought to be verified. A stopwatch ought to be used for confirming periods of time. ? The satisfactory operation of the fuel control solenoid valves for all requirements of operation and shutdown should be verified. ? A low voltage test ought to be run on…
Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses. HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste. Requirement 20% -25% of the full waste created by medical treatment facilities is associated to as hazardous and also might develop a selection of health as well as environmental threats if not managed and also harmed in a correct means. Our products ensure reliable, neat as well as very simple disposal of clinical…
The incinerator fuel tank shall meet the following requirements: a) The tank shall be installed above ground and according to all of the fuel tank requirements in Section 1015 including secondary containment. b) The tank shall be sized to hold a 14 day supply of diesel fuel 6) Manufacturer has to provide the following…
Incinerator dual chamber with capacity 1.5 m3/batch or 6 m3/ day, electronic thermocontrol range 0‐1200 C, thermocouple, air supply capacity 10m3/ minute, electricity consumption 1.2kWH/ hour, power 3 phase with netral, cooling water sprinkler capacity 5L/ minute, completed with refractory (insulation, castable, ceramic blanket) and PLC SUPPLY, INSTALLATION AND COMMISSIONING OF WASTE INCINERATOR — TECHNICAL…
The successful bidder will deliver the incinerator slide in a container. A containerized alternative is also acceptable. incinerator with a closed air surroundings, Electrically operated 220 volt ( 60 Cycle – 1 phaze ) Able to complete burning material that turns to ashes all the component elements of the carbon or metal in the waste,…
https://gudaobian.net/incineration/medical-incinerators-in-china/